Edgewater Networks 4200 Series Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
Page 21
Implementation Steps
Utilizing the EdgeMarc GUI, follow the standard instructions (described in the user’s
guide) to enable the following on the EdgeMarc:
1.
Enable Network with VLAN functionality
o
Set LAN Port 2 to 802.1q framing.
Set LAN Ports 1, 3 and 4 to 802.1 framing.
o
Leave VLAN 2730 as management port:
IP Address: 192.168.1.1 with mask 255.255.255.0
o
Add a VLAN with:
ID: 200
IP address: 10.10.10.1 with mask 255.255.255.0
o
Add a VLAN with:
ID: 2
IP address: 10.0.0.1 with mask 255.255.255.0
o
Associate VLAN 2730 with LAN ports 1 and 4
o
Associate VLAN 200 with LAN port 2
o
Associate VLAN 2 with LAN port 3
When done, the VLAN screen should look similar to the following:
VLAN Configuration Page:
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 30 31

Comentarios a estos manuales

Sin comentarios